CONTOUR®NEXT EZ

Adaptable to every need, from basic to advanced, for simple diabetes management.

Product Features

  • Ready to use straight out of the box
  • Test execution in 5 seconds (countdown)
  • Small blood sample required (0.6 µl)
  • Memory for 480 results
  • No Coding Technology ensures an accurate reading every test

Why choose CONTOUR®NEXT EZ?

Easy to use

Easy to use

Intuitive design and easy-to-read display. Pre-configured for immediate use.

accurate

An accurate and convenient blood glucose meter

  • Rapid test results: Delivers accurate blood glucose readings1,‡ within 5 seconds, supported by a countdown timer.
  • Second-Chance® sampling: Simply add more blood to the same strip if the first sample is not enough, helping to prevent wasted strips.2

Memory for 480 results

  • Averages over 7, 14, and 30 days
  • High (HI) and low (LO) value summaries from the past 7 days
  • Pre- and post-meal markers with optional post-meal reminders
  • Data download to PC via the Glucocontro.online glucose data management portal

How to use*

Testing in 3 simple steps

Step 1

Insert CONTOUR®NEXT test strip and the meter will switch on.

Step 2

Lightly touch the test strip to the drop of blood and hold until the meter beeps.

Step 3

The test result will display after a 5-second countdown. To turn the meter off, simply remove the test strip

Instructional Video

Works with

CONTOUR®NEXT strips

CONTOUR®NEXT strips, boxes of 100 or 50 strips

MICROLET®NEXT lancing device

MICROLET®NEXT lancing device with MICROLET® lancets

FAQs

Do you have questions concerning the CONTOUR®NEXT EZ blood glucose meter? Have a look at our FAQs here.

Contact us

Would you like to know more about one of our products? Visit our contact us page.

CONTOUR®NEXT EZ meter meets ±10% accuracy vs. laboratory method, specifically: 99.5% of results within ±10% for blood glucose concentrations ≥5.55 mmol/L, and 100% of results within ±0.56 mmol/L accuracy vs. laboratory method for blood glucose concentrations <5.55 mmol/L.

*See CONTOUR®NEXT EZ user guide for full instructions before use.

1. Current regulation based on Health Canada recognized ISO 15197:2013 standard requires results within ±15% range, specifically: ≥95% of results must fall within ±0.83 mmol/L for blood glucose concentrations <5.55 mmol/L and within ±15% for blood glucose concentrations ≥5.55 mmol/L.

2. Richardson JM et al. Clinical Relevance of Reapplication of Blood Samples During Blood Glucose Testing. Poster presented at the 20th Annual Diabetes Technology Meeting (DTM); November 12-14, 2020.